English German
 

 

Netzteile
Wechselrahmen
Raid Module
Card Reader
 
Zippy P2G-5600G 2U Single
Peripheriegeräte > Netzteile > Zippy > P2G-5600G


P2G-5600G
 
  • Output Wattage : 600W
  • Best Solution for: Server, Workstation, Storage System, IPC
  • Dimension:
    240.00 x 100.00 x 70.00 (mm)
    9.45 x 3.94 x 2.76 (inch)
 
AC INPUT SPECIFICATION
 
  • VOLTAGE: 90 ~ 264VAC FULL RANGE
  • FREQUENCY : 47 ~ 63 HZ
  • INPUT CURRENT: 9A(RMS) FOR 115VAC, 4.5A(RMS) FOR 230 VAC
  • INRUSH CURRENT: 50A MAX. FOR 115 VAC, 100A MAX. FOR 230 VAC
  • POWER FACTOR CORRECTION: PFC CAN REACH THE TARGET OF 95% AT 115/230VAC, FULL LOAD
  • DC INPUT SPECIFICATION
    OUTPUT VOLTAGE
    OUTPUT CURRENT
    REGULATION
    OUTPUT
    MIN.(A)
    MAX.(A)
    LOAD
    LINE
    RIPPLE & NOISE
    MAX.[P-P]
    +5V
    0.5
    25
    ±5%
    ± 1%
    60mV
    +12V
    2
    48
    ±5%
    ± 1%
    120mV
    -12V
    0
    0.5
    ±5%
    ± 1%
    120mV
    +3.3V
    0.5
    25
    ±5%
    ±1%
    60mV
    +5VSB
    0.05
    3
    ±5%
    ± 1%
    60mV
    Remarks:
    * +5V AND +3.3V TOTAL OUTPUT MAX: 160W
    * +5V, +3.3V AND +12V TOTAL MAX: 581.5W
    * TOTAL POWER: 600W

     

    • TEMPERATURE RANGE: OPERATING 0℃ --- 50℃, STORAGE –20℃ --- 80℃
    • HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
    • EFFICIENCY: 87~90%  TYPICAL AT 115V, FULL LOAD
    • LEAKAGE CURRENT: 3.5mA MAX. AT NOMINAL VOLTAGE VAC
    • POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
    • OVER POWER PROTECTION: 110~160%
    • OVER VOLTAGE PROTECTION: +3.3V→3.6~4.3V, +5V→5.6~6.5V, +12V→13.2~15V
    • OVER CURRENT PROTECTOIN: +3.3V→27.5~40A, +5V→27.5~40A, +12V→52.8~72.8A
    • SHORT CIRCUIT PROTECTION
    • EMI: FCC CLASS B, CISPR22 CLASS B
    • SAFETY: TO MEET UL, CUL, TV, CCC
    • 3.3V / 5V / 12V REMOTE SENSING
    • COOLING: ONE 60mm DC FAN
    • DIMENSION: 240 (D) x 100 (W) x 70 (H) mm
    • MEET IEC-1000-3-2 CLASS D
    • *THE POWER-SUPPLY IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC- AND SAFETY-REGULATIONS.