English German
 

 

Netzteile
Raid Module
Card Reader
 
Zippy R3G-5800P4V N+1 Redundant
Peripheriegeräte > Netzteile > Zippy > R3G-5800


R3G-5800P4V

 

  • Certificate
  • Structure
    • Output Wattage: 800W
    • Lösung für: Server
    • Abmessungen:
      276.00 x 150.00 x 86.00 (mm)
      10.87 x 5.00 x 3.27 (inch)
    AC INPUT SPECIFICATION
     
  • VOLTAGE: 90 ~ 264VAC FULL RANGE
  • FREQUENCY : 47 ~ 63 HZ
  • INRUSH CURRENT: 40A MAX. FOR 115 VAC PER MODULE
  • 60A MAX. FOR 230 VAC PER MODULE
  • DC INPUT SPECIFICATION
    OUTPUT VOLTAGE
    OUTPUT CURRENT
    REGULATION
    OUTPUT
    MIN.(A)
    MAX.(A)
    LOAD
    LINE
    RIPPLE & NOISE
    MAX.[P-P]
    +5V
    1
    45
    ± 5%
    ± 1%
    50mV
    +12V
    1.5
    49
    ± 7%
    ± 1%
    120mV
    -12V
    0.01
    1
    ± 10%
    ± 1%
    150mV
    +3.3V
    1
    38
    ± 5%
    ± 1%
    50mV
    +5VSB
    0.1
    4
    ± 5%
    ± 1%
    50mV

     

    • Active PFC (full range), MEET IEC-1000-3-2 CLASS D
    • TEMPERATURE RANGE: OPERATING 0°~40°, STORAGE -20~70°
    • HOLD UP TIME:16mS MINIMUM AT FULL LOAD & 90 VAC INPUT VOLTAGE
    • DIELECTRIC WITHSTANDING: INPUT/OUTPUT 1500 VAC FOR 1 MINUTE INPUT TO FRAM GROUND 1500 VAC FOR 1 MINUTE
    • EFFICIENCY: 70% TYPICAL, AT FULL LOAD
    • POWER GOOD SIGNAL:ON DELAY 100mS TO 550mS, OFF DELAY 1mS
    • OVER POWER PROTECTION:110~160% MAX
    • OVER VOLTAGE PROTECTION: +5V → 5.7V ~ 6.5V, +3.3V → 3.9V ~ 4.7V, +12V → 13.3V ~ 14.3V
    • SHORT CIRCUIT PROTECTION: 5V, 12V, 3.3V,AUTO-RECOVERED: 5VSB, -12V
    • SAFETY: MEET UL 60950, CSA 60950, TUV EN-60950
    • Remote on/off control
    • FAULTY ALARM METHODS: LED, BUZZER, TTL SIGNAL
    • 2+1, HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
    • N+1 BALANCE LOAD SHARING DESIGN ON 5/12/3.3V CHANNEL
    • REMOTE SIGNAL DESIGN
    • ISOLATION: BUILT-IN THE POWER MODULE
    • COOLING: TWO 40 mm DC FANS (ONE IN EACH MODULE)