|
|
|
|
Zippy M1P2-5500V4V 2U Redundant |
Peripheral
> Power Supply > Zippy >M1P2-5500V4V
|
|
|
- Output Wattage: 500W
- Best Solution for: Server, Workstation, Storage System, IPC
- Dimension:
217.00 x 85.00 x 84.00 (mm)
8.54 x 3.35 x 3.31 (inch)
|
|
|
AC INPUT SPECIFICATION |
|
VOLTAGE:90
~ 264VDC
FREQUENCY: 47~63HZ
STEADY-STATE CURRENT: 8/4A MAX AT ANY
LOW/HIGH VOLTAGE
INRUSH CURRENT: 40/60A @ 115/230VAC
|
|
DC INPUT SPECIFICATION |
OUTPUT VOLTAGE
|
OUTPUT CURRENT
|
REGULATION
|
OUTPUT
|
MIN.(A)
|
MAX.(A)
|
LOAD
|
LINE
|
RIPPLE & NOISE
MAX.[P-P]
|
+5V
|
0.5
|
32
|
± 5%
|
± 1%
|
50mV
|
+12V
|
2
|
41
|
± 5%
|
± 1%
|
120mV
|
-12V
|
0.1
|
0.5
|
±10%
|
± 1%
|
150mV
|
+3.3V
|
0.5
|
25
|
± 5%
|
± 1%
|
50mV
|
+5VSB
|
0.1
|
3.5
|
±5%
|
± 1%
|
50mV
|
Remarks:
* +5V AND +3.3V TOTAL OUTPUT MAX: 170W
|
|
- TEMPERATURE RANGE:OPERATING 0℃~40℃, STOREAGE -20℃~80℃
- HOLD UP TIME:16mS IN REGULATOIN LIMIT AT 90VAC INPUT VOLTAGE
- EFFICIENCY(PER SET):POWER SUPPLY EFFICIENCY TYPICAL >80% AT 230V, FULL LOAD
- OUTPUT PROTECTION: OPP / OVP / SCP / OCP
- REMOTE ON / OFF CONTROL
- BALANCE LOAD SHARING DESIGN
- HOT-SWAPPABLE/HOT PLUGGABLE REDUNDANCY FUNCTION
- ISOLATION: BUILT-IN THE POWER MODULE
- FAULTY ALARM METHODS: BUZZER, TTL SIGNAL
- EMI: IEC61000-3-2, FCC, CISPR 22(EN 55022)
- EMS: EN 61000-4-2 ESD, EN61000-4-4 EFT, EN61000-4-5 SURGE
- SAFETY APPROVAL: UL, CUL, TUV, CCC
- *THE POWER-SUPPLY
IS FOR CHASSIS-ASSEMBLY ONLY AND IS NOT ALLOWED
TO BE OPERATED AS STAND-ALONE COMPONENT. FINAL
ASSEMBLY HAS TO COMPLY WITH CORRESPONDING EMC-
AND SAFETY-REGULATIONS.
|
|
|
|