Zippy RHD-6460P PS/2 Redundant |
Peripheriegeräte
> Netzteile > Zippy > RHD-6460P
|
|
|
- Output Wattage: 460W
- Anschlüsse:
ATX 2.03, ATX12V(P4), EPS12V, WTX, AMD-GES
- Lösung für:
Server, Workstation, Storage System, IPC
- Abmessungen:
213.2(H) X 153.4(B) X 183(T) mm
|
|
|
AC INPUT SPECIFICATION |
|
VOLTAGE: 90 ~ 264VAC FULL RANGE
FREQUENCY: 47 ~ 63HZ
INPUT CURRENT : 8.0 / 4.0 A FOR 115 /
230 VAC PER MODULE
INRUSH CURRENT: 65A / 125A MAX. FOR 115
/ 230 VAC PER MODULE
|
|
DC INPUT SPECIFICATION |
OUTPUT VOLTAGE
|
OUTPUT CURRENT
|
REGULATION
|
OUTPUT
|
MIN.(A)
|
MAX.(A)
|
LOAD
|
LINE
|
RIPPLE & NOISE
MAX.[P-P]
|
+5V
|
5.0
|
35/40
|
± 5%
|
± 1%
|
60mV
|
+12V
|
2.5
|
20/32
|
± 5%
|
± 1%
|
100mV
|
-5V
|
0
|
0.8
|
± 5%
|
± 1%
|
100mV
|
-12V
|
0
|
1
|
± 5%
|
± 1%
|
100mV
|
+3.3V
|
1.0
|
28/30
|
± 5%
|
± 1%
|
60mV
|
+5VSB
|
0.1
|
2.0
|
± 5%
|
± 1%
|
60mV
|
Remarks: XX / XX
: 400W / 460W;
* TOTAL POWER OUTPUT NOT EXCEED 400 / 460W |
|
- TEMPERATURE RANGE: OPERATING 0oC
-- 40oC ; STORAGE - 20oC
-- 70oC
- HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD &
NORMAL INPUT VOLTAGE
- DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500
VAC FOR 1 MINUTE INPUT TO FRAME GROUND
1500 VAC FOR 1 MINUTE
- EFFICIENCY: 65% TYPICAL, AT FULL LOAD
- POWER GOOD SIGNAL: ON DELAY 100 ms TO 500
ms, OFF DELAY 1 ms
- OVER LOAD PROTECTION: 110 ~ 160% MAX.
- OVER CURRENT PROTECTION : 6 CHANNELS
- OPEN LOOP PROTECTION
- SHORT CIRCUIT PROTECTION DOUBLE OVER VOLTAGE
PROTECTION :
+5V
5.7V ~ 6.5V, 3.3V
3.9 ~ 4.3V, 12V
13.6 ~ 15V
- EMI NOISE FILTER: FCC CLASS B, CISPR22 CLASS
B
- SAFETY: UL 1950, CSA 22.2 NO/ 950, TUV IEC
950
- REMOTE ON / OFF CONTROL
- FAULTY ALARM METHODS : LED, BUZZER, TTL SIGNAL
- HOT-SWAPPABLE / HOT-PLUGGABLE 1 + 1 REDUNDANCY
FUNCTION
- BUILT-IN ACTIVE POWER FACTOR CORRECTOR
- DIMENSION:
213.2(H) X 153.4(W) X 183(D) mm--RHD;
189(H) X 167(W) X 183(D) mm--RHI;
106(H) X 354(W) X 194.2(D) mm--RHH
- COOLING : TWO 80 mm DC FANS
- USED 48 PINS INDUSTRIAL CONNECTORS
|
|
|
|